Lenticular Filter Module 2019-10-29T15:43:10+00:00

Lenticular Filter Module

Applications

  • Pharmaceutics
  • Food & Beverage
  • Fine Chemical
  • Wine Filtration
Request PDF

Description

  • Shuler’s Lenticular Filter Cartridges consist of cellulose with special polymer binders.

  • Two types are available: cellulose with diatomite, cellulose with activated carbon.

  • LMF Lenticular filter cartridges are manufactured in φ8”, 12” and 16”, each containing 16 cells the most.

  • Due to their high particle retention the LMF lenticular filters are ideally suited for numerous applications in removing colloidal impurities, or as pre-filters to protect and relieve fine filter cartridges.

Specification

Dimension OD: 8”, 12”,16”
Material of Construction Depth Filter Sheet: CD: Cellulose with diatomaceous earths
                        CA: Cellulose with activated carbon
Core: PP
Gasket: Silicone, EPDM, Viton
Micron Rating M02: 0.2-0.4μm M04: 0.4-0.6μm
M10: 1-3μm M20: 2-5μm
M30: 3-7μm
Differential Pressure Max. 2bar@20℃
Sterilisation Autoclave or steam at 121℃, 30min

Ordering Information

Code Filter Sheet
Material
OD Filter Sheet Qty Micron Rating Gaskets
LMF CD=Cellulose with
  diatomite
08=8” 7=7 Cell M02 = 0.2-0.4μm S=Silicone
CA=Cellulose with
active carbon
12=12” 8=8 Cell M04 = 0.4-0.6μm E=EPDM
C=Cellulose 16=16” 9=9 Cell M10 = 1-3μm B=NBR
    12=12 Cell M20 = 2-5μm  
    14=14 Cell M30 = 3-7μm  
    15=15 Cell    
    16=16 Cell    

Let us know your request and get more information about Omni watermaker.

Contact Shuler Now